Designed to eliminate and protect against moisture and contaminants in gear units, lubricated reservoirs, and electrical transformers

You're here : Home / DES-CASE Europe / GENERAL DATA / GENERAL / MAINTENANCE

MAINTENANCE

E. Maintenance:
When the body of the breather will be pink (or white if you wait too much) replace the breather by a new one.
Typical normal change of color:
Agrandir

Always use the DESCASE desiccant breathers on reservoirs that contain non polluated lubricant. In that case the average duration will be about 12 month (After 15 years of feedvack in Europe, average duration is about 14 months, 8 to 18 months). DESCASE units must turn, from blue to pink (or white), from the bottom to the top (as shown on the right of the picture). If you use DESCASE units on polluated reservoirs, in addition you will see breathers turned pink from the top (as shown on the left of the picture); it means and proves that there is a certain amount of water or moisture inside reservoirs. In that case the duration of DESCASE units may be devided by 10.
AgrandirAgrandir

How units must change of colorInstaller Foxit pdf Reader Installer pdf Acrobat Reader 176.53 Ko
How to understand and explanation on colour changesInstaller Foxit pdf Reader Installer pdf Acrobat Reader 1355.9 Ko
Solution-problem-detectionInstaller Foxit pdf Reader Installer pdf Acrobat Reader 539.53 Ko

 